- Overview
- Product Description
- Construction feature
- Certifications
- Company Profile
- Our Advantages
- Conditions of use
- Engineering cases
- Reception of Foreign Merchants
Basic Info.
Product Description
Purpose
GCS low voltage withdrawable switch cabinet is a modular distribution device. There are two types of structure. One is the outgoing switch installed in the drawer which can be drawn out and connected to the bus by plug-ins; the other is the insert plastic shell switch installed in the fixed interval where the front door can be opened. The withdrawable switch cabinet of two kinds of structures can be repaired under the condition of other electrified interval, and the same module can be exchanged. Operators and charged bodies strictly separated, high safety. Suitable for power plant, substation, petrochemical industry, factory and mining enterprises and high-rise building departments, as three-phase AC frequency of 50 (60) Hz rated working voltage to 380V power system power, power distribution and motor control center, capacitance compensation and other power conversion, distribution and control. Can also meet the needs of automatic user and computer interface.
Characteristic
- The cabinet body is made of 2.0mm galvanized steel plate, which is composed of modular steel frame and assembled without welding. The door and sealing plate are made of environmental protection plastic spraying technology without chemical treatment.
- The energy unit room, bus room and cable room are separated by steel plate, and the functional compartments are strictly separated.
- The horizontal bus is placed in the bus room on the top of the cabinet.
- Drawer and switch position and state are clearly marked, and each position can be locked.
- Single cabinet out of the circuit many, up to 22.
- Products comply with iec439-1, G7251, zbk36001-89 standards.
After the device arrives at the receiving location, it should first check whether the packaging is intact. If problems are found, the relevant departments of the contract should be notified in time to make business records, analyze the reasons together, and make visas and aftercare.Products that are not installed immediately should be placed in an appropriate place in accordance with normal use conditions or electrical equipment storage regulations, and kept in a safe place.
Generally, it is assembled by a single unit or 2-5 power distribution cabinets. The width of the parallel assembly unit is less than or equal to 3000mm, the depth is 840mm or 1040mm, and the height is 2300mm (excluding the outer packaging and outer dimensions.
The installation should be carried out according to the schematic diagram (see FIG. 3). If the cable goes out, the external dimensions of the cable trench should be carried out according to FIG. 4.
The installed foundation plane shall be flat, the horizontal error of the foundation channel steel shall be 1/1000, and the total length deviation shall be ±3mm.
During installation, the main bus connection should be made according to the drawings, and the surface of the main bus should be cleaned, and then tightened with bolts, and cable or overhead wire wiring work
When the rated current of the busbar bridge is 5002500A and the middle net span is greater than 2500mm, a sling shall be installed between the roofs of the power distribution room in the center of the bridge. See Figure5.
- The frame of the device is a combined structure, and the basic skeleton is assembled by a c-profile with a modulus of e=20, and is fastened by a self-tapping locking screw or a 8.8-level hex bolt to form a basic frame, and a door corresponding to the change of the scheme, The partition, the sealing plate, the mounting bracket and the busbar functional unit are assembled into a complete device, which has high mechanical strength, no deformation of the single cabinet, and an open shape of the profile steel, which easily achieves the purpose of pre-treatment.
- The cabinet is divided into three compartments, namely the horizontal busbar compartment (at the rear of the cabinet), the functional unit room (at the front of the cabinet), the cable compartment (in the lower part of the cabinet or the front of the cabinet), and the chamber and chamber supports are plated. The zinc plate or the high-strength flame-retardant plastic function board are separated from each other, and the functions of the respective chambers are relatively independent; the metal plates with ventilation holes between the upper and lower drawer functional units are isolated to effectively prevent the arcing of the electrical components from being short-circuited with the busbar or other lines due to malfunction. The accident caused.
- The horizontal busbar adopts the rear arrangement of the cabinet to increase the capacity of the busbar to resist electric power, so that the main circuit of the device has high short-circuit strength capability.
- Classification of incoming and outgoing lines: up and down, up and down, down and down, down and up.The cable compartment is designed to make it easy to access the cable up and down.
- The short-circuit strength value of the main structure reaches the rated short-time withstand current of 80ka and the rated peak withstand current of 176ka, which can match the current and future transformer capacity (2500kva).
- A large number of new and more reasonable structural parts and components have been used in large quantities, and special parts are mass-produced by dedicated factories to ensure quality and standardized production.
- In order to reduce the temperature rise of the connector, cable head and partition plate of the functional unit, the special adapter for the gcs cabinet is designed. Compared with similar products, the heat capacity is increased and the temperature rise is reduced.
- The device is designed according to three-phase five-wire system or three-phase four-wire system. The design department and users can conveniently select pe+n or pen mode.
Chongqing Lianwei Power Technology development Co., Ltd.(Tongxun Power Industry Co., Ltd.) was established in April 1989, located in Lidu Industrial Park, Fuling District, Chongqing. It has a 30-year history of production and development of complete electrical equipment. The company's predecessor is Fuling Three Gorges Electric Appliance Factory of Chongqing Yuneng Group, which was later assigned to Chongqing East Asia Group. In 2006, it was transformed into Chongqing Dixun Electric Technology Co., Ltd. and in 2013, it was renamed Chongqing Taiwei Electric Equipment Co., Ltd. in October 2015, it was reorganized into Chongqing Lianwei Power Technology development Co., Ltd.(Tongxun Power Industry Co., Ltd.)with wholly-owned subsidiaries of Lanzhou Changyao Distribution Engineering Co., Ltd., Lanzhou Guowei Power Supply Co., Ltd. and Chongqing Lianwei Power Technology Development Co., Ltd. The company is a group with integrated the general contracting of electric power projects, the loading, repairing, testing, manufacturing of electric power equipment, operation and maintenance of electric power systems and import and export trade.
Since 1989, being in line with the "Honesty and Trustworthy, customer first" corporate purpose and adherence to the "innovative, pragmatic, pioneering and enterprising" spirit, the company has shaped the "integrity, excellence, exquisite, value" brand image. Since 2000, the company has been successively awarded the following honorary titles: "Quality Designated Demonstration Unit", "Chongqing Famous Product", "Best District Civilization Unit", "A Class Taxpayer", and "National Quality Stable Qualified Product". The company has one patent for invention and six patents for utility model.
Chongqing Lianwei Power Technology development Co., Ltd.(Tongxun Power Industry Co., Ltd.) is looking forward to working with you to create a bright and brilliant tomorrow with good corporate reputation, excellent .
- The ambient air temperature is not higher than +40 ° C, not lower than -5 ° C, the average temperature within 24 hours shall not be higher than +35 ° C.When it is exceeded, it needs to be derated according to the actual situation.
- For indoor use, the altitude of the place of use shall not exceed 2000m.
- The relative humidity of the surrounding air does not exceed 50% at a maximum temperature of +40 ° C, and allows a relatively large relative humidity at a lower temperature, such as 90% at +20 ° C. It should be considered that the temperature may change by chance. The effect of condensation.
- When the device is installed, the inclination to the vertical plane is not more than 5%, and the entire group of cabinets is relatively flat.
- The unit shall be installed in a location where there is no violent vibration and shock and insufficient to subject the electrical components to undue corrosion.
- When the user has special requirements, it can be resolved in consultation with the manufacturer.